>> Next

 

Aga Rayburn Cooker Specifications.

The depth of colour and durability of the Rayburn enamel finish is legendary - it's the reason why Rayburns built many years ago still retain their original good looks.

Rayburn Cookmaster

Model
Function
Fuel
Controls
Initial Flue Pipe
(min internal
diameter)
Ventilation
(min air vent
to room)
Water
Output
Hot Water
System
Electrical
Supply
Water
Cylinder
Size
Weight
200G/L*
C
Natural
Gas/LPG
(Propane)
Thermostatic
(optional wall
programmer)
Conventional
102mm (4")
36cm sq
(14.2" sq)
N/A
N/A
230V-50Hz
5 amp fused
N/A
275Kg
(606lb)
200KV
C
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Manual
Conventional
102mm (4")
30.5cm sq
(12" sq)
N/A
N/A
No
N/A
305Kg
(672lb)
200S
C
Smokeless
selected
bituminous
coals
Manual
Conventional
127mm (5")
126cm sq
(49.6" sq)
N/A
N/A
No
N/A
319Kg
(703lb)
300K#
C
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Manual
Conventional
102mm (4")
30.5cm sq
(12" sq)
N/A
N/A
No
N/A
300Kg
(661lb)
400K#
C
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral oven
timer. (optional
wall programmer)
Conventional
127mm (5")
61cm sq
(24" sq)
N/A
N/A
220-240V-50Hz
3 amp fused
N/A
345Kg
(760lb)
400G*#
C
Natural Gas
Integral oven
timer. (optional
wall programmer)
Conventional
127mm (5")
35cm sq
(13.8" sq)
N/A
N/A
220-240V-50Hz
3 amp fused
N/A
345Kg
(760lb)
400K P/F
C
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral oven
timer. (optional
wall programmer)/
Thermostatic
Power
 
N/A
N/A
220-240V-50Hz
3 amp fused
N/A
345Kg
(760lb)
400G P/F
C
Natural Gas
Integral oven
timer. (optional
wall programmer)/
Thermostatic
Power
 
N/A
N/A
220-240V-50Hz
3 amp fused
N/A
345Kg
(760lb)

Key to product codes:
G=Natural Gas | L=Propane Gas | K=Kerosene Oil | D=Diesel Oil | S=Solid Fuel | M=Multi Solid Fuel | A=Atmospheric Gas Burner | C=Cooking

Technical Image#1 Technical Image#2 Technical Image#3

Rayburn Cookmaster Plus

Model
Function
Fuel
Controls
Initial Flue Pipe
(min internal
diameter)
Ventilation
(min air vent
to room)
Water
Output
Hot Water
System
Electrical
Supply
Water
Cylinder
Size
Weight
208KV
C/DHW
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Manual
Conventional
102mm (4")
30.5cm sq
(12" sq)
8,000Btu/h
2.3kW
Gravity
230V-50Hz
5 amp fused
N/A
275Kg
(606lb)
208G/L*
C/DHW
Natural
Gas/LPG
(Propane)
Manual
Conventional
102mm (4")
36cm sq
(14.2" sq)
8,000Btu/h
2.3kW
Gravity
No
N/A
305Kg
(672lb)
212SV
C/DHW
Smokeless
selected
bituminous
coals
Manual
Conventional
127mm (5")
126cm sq
(49.6" sq)
12,000Btu/h
3.5kW
Gravity
No
N/A
319Kg
(703lb)
308K#
C/DHW
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Manual
Conventional
102mm (4")
30.5cm sq
(12" sq)
8,000Btu/h
2.3kW
Gravity
No
N/A
300Kg
(661lb)

Key to product codes:
G=Natural Gas | L=Propane Gas | K=Kerosene Oil | D=Diesel Oil | S=Solid Fuel | M=Multi Solid Fuel | A=Atmospheric Gas Burner | C=Cooking | DHW=Domestic Hot Water

Technical Image#1 Technical Image#2

Rayburn Heatranger

Model
Function
Fuel
Controls
Initial Flue Pipe
(min internal
diameter)
Ventilation
(min air vent
to room)
Water
Output
Hot Water
System
Electrical
Supply
Water
Cylinder
Size
Weight
THE HEATRANGER 400 RAPID RESPONSE
460K#
460KB#
C/DHW/CH
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral
Programmer
Conventional
127mm (5")
Balanced Flue
*146.9cm sq
(57.8" sq)
60,000Btu/h
17.6kW
12 Radiators
Fully pumped
open & sealed
systems
220/240V-50Hz
5 amp fused
Suitable for
most sizes
395Kg
(870lb)
480K#
480KB#
C/DHW/CH
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral
Programmer
Conventional
127mm (5")
Balanced Flue
146.9cm sq
(57.8" sq)
80,000Btu/h
23.4kW
16 Radiators
Fully pumped
open & sealed
systems
220/240V-50Hz
5 amp fused
Suitable for
most sizes
395Kg
(870lb)
499K#
499KB#
C/DHW/CH
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral
Programmer
Conventional
127mm (5")
Balanced Flue
211.2cm sq
(83" sq)
100,000Btu/h
29.3kW
20 Radiators
Fully pumped
open & sealed
systems
220/240V-50Hz
5 amp fused
Suitable for
most sizes
395Kg
(870lb)
440K
C/DHW/CH
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral
Programmer
/Thermostatic
Conventional
127mm (5")
Balanced Flue
40,000Btu/h
11.7kW
8 Radiators
Fully pumped
open & sealed
systems
220/240V-50Hz
5 amp fused
Suitable for
most sizes
395Kg
(870lb)
440KB
C/DHW/CH
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Integral
Programmer
/Thermostatic
Conventional
127mm (5")
Balanced Flue
40,000Btu/h
11.7kW
8 Radiators
Fully pumped
open & sealed
systems
220/240V-50Hz
5 amp fused
Suitable for
most sizes
395Kg
(870lb)
HEATRANGER TRADITIONAL
480AL(CF)*
C/DHW/CH
Propane Gas
Optional
External
Programmer
Conventional
127mm (5")
144cm sq
(57" sq)
60-80,000
Btu/h
17.6-23.4kW
16 Radiators
Fully pumped
open & sealed
systems
230V-50Hz
3 amp fused
Suitable for
most sizes
350Kg
(771lb)
480AG(CF)*
C/DHW/CH
Natural Gas
Optional
External
Programmer
Conventional
127mm (5")
144cm sq
(57" sq)
60-80,000
Btu/h
17.6-23.4kW
16 Radiators
Fully pumped
open & sealed
systems
230V-50Hz
3 amp fused
Suitable for
most sizes
350Kg
(771lb)
368K#
C/DHW/CH
Commercial
Kerosene 28
seconds to
BS2869
Class C2
Thermostatic
Conventional
127mm (5")
82.5cm sq
(32.5" sq)
68,500 Btu/h
20kW
14 Radiators
Gravity DHW
& pumped
systems
230V-50Hz
3 amp fused
190 Litres
(40 Gallons)
340Kg
(750lb)
355M
C/DHW/CH
Smokeless
selected
bituminous
coals, dry wood
& peat briquettes
Thermostatic
& Manual
Conventional
153mm (6")
182cm sq
(72" sq)
55,0000Btu/h
16.1kW
12 Radiators
Gravity DHW
& pumped
systems
No
190 Litres
(40 Gallons)
340Kg
(750lb)
216M
C/DHW/CH
Smokeless
selected
bituminous
coals, dry wood
& peat briquettes
Manual
Conventional
127mm (5")
126cm sq
(49.6" sq)
16,000 Btu/h
4.7kW
2-3Radiators
Gravity DHW
& pumped
systems
No
190 Litres
(40 Gallons)
305Kg
(672lb)

Key to product codes:
G=Natural Gas | L=Propane Gas | K=Kerosene Oil | D=Diesel Oil | S=Solid Fuel | M=Multi Solid Fuel | A=Atmospheric Gas Burner | C=Cooking | DHW=Domestic Hot Water | CH=Central Heating | B=Balanced Flue